ABB TTR200 Instructions d'exploitation

Naviguer en ligne ou télécharger Instructions d'exploitation pour Mesure, test et contrôle ABB TTR200. ABB TTR200 Operating instructions Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Temperature Transmitte

SIL-Safety Instructions SM/TTX200/TTX300/SIL-EN Temperature TransmitterTTH200, TTR200, TTH300, TTF300, TTF350 Information about functional safet

Page 2 - SIL-Safety Instructions

Safety function 10 TTH200, TTR200, TTH300, TTF300, TTF350 SM/TTX200/TTX300/SIL-EN The DCS power supply for the transmitter must be capable of prov

Page 3

Safety function SM/TTX200/TTX300/SIL-EN TTH200, TTR200, TTH300, TTF300, TTF350 11 6.2 Measuring point for SIL 3 – Dual configuration Two transmitt

Page 4 - 1 Field of Application

Periodic checks 12 TTH200, TTR200, TTH300, TTF300, TTF350 SM/TTX200/TTX300/SIL-EN 7 Periodic checks Safety inspections The safety function for

Page 5 - Acronyms and abbreviations

Configuration SM/TTX200/TTX300/SIL-EN TTH200, TTR200, TTH300, TTF300, TTF350 13 K 8 Configuration The device has been configured and tested accor

Page 6 - Acronyms and abbreviations

Configuration 14 TTH200, TTR200, TTH300, TTF300, TTF350 SM/TTX200/TTX300/SIL-EN WARNING! Checks: Write protection must be checked as follows: 1.

Page 7 - 3 Relevant standards

Configuration SM/TTX200/TTX300/SIL-EN TTH200, TTR200, TTH300, TTF300, TTF350 15 Configuration parameters affecting the safety function All configur

Page 8 - 5 Terms and definitions

SIL 2 TÜV-Certificate 16 TTH200, TTR200, TTH300, TTF300, TTF350 SM/TTX200/TTX300/SIL-EN 9 SIL 2 TÜV-Certificate 10 Namur NE 93 TTH200-.

Page 9 - 6 Safety function

Management summary FMEDA – Failure modes, effects, and diagnostic analysis SM/TTX200/TTX300/SIL-EN TTH200, TTR200, TTH300, TTF300, TTF350 17 11

Page 10 - Safety function

Management summary FMEDA – Failure modes, effects, and diagnostic analysis 18 TTH200, TTR200, TTH300, TTF300, TTF350 SM/TTX200/TTX300/SIL-EN

Page 11 - Safety function

Management summary FMEDA – Failure modes, effects, and diagnostic analysis SM/TTX200/TTX300/SIL-EN TTH200, TTR200, TTH300, TTF300, TTF350 19

Page 12 - 7 Periodic checks

Blinder Text 2 TTH200, TTR200, TTH300, TTF300, TTF350 SM/TTX200/TTX300/SIL-EN Temperature Transmitter TTH200, TTR200, TTH300, TTF300, TTF350 SIL

Page 13 - 8 Configuration

Management summary FMEDA – Failure modes, effects, and diagnostic analysis 20 TTH200, TTR200, TTH300, TTF300, TTF350 SM/TTX200/TTX300/SIL-EN

Page 14 - Configuration

Management summary FMEDA – Failure modes, effects, and diagnostic analysis SM/TTX200/TTX300/SIL-EN TTH200, TTR200, TTH300, TTF300, TTF350 21

Page 15

Management summary FMEDA – Failure modes, effects, and diagnostic analysis 22 TTH200, TTR200, TTH300, TTF300, TTF350 SM/TTX200/TTX300/SIL-EN

Page 17

ABB has Sales & Customer Support expertise in over 100 countries worldwide. www.abb.com/temperature The Company’s policy is one of contin

Page 18

Contents SM/TTX200/TTX300/SIL-EN TTH200, TTR200, TTH300, TTF300, TTF350 3 1 Field of Application...

Page 19

Field of Application 4 TTH200, TTR200, TTH300, TTF300, TTF350 SM/TTX200/TTX300/SIL-EN 1 Field of Application Temperature monitoring of solids,

Page 20

Acronyms and abbreviations SM/TTX200/TTX300/SIL-EN TTH200, TTR200, TTH300, TTF300, TTF350 5 Acronym/ Abbrevia-tion English Description SIL Safety

Page 21

Acronyms and abbreviations 6 TTH200, TTR200, TTH300, TTF300, TTF350 SM/TTX200/TTX300/SIL-EN Acronym/ Abbrevia-tion English Description closed c

Page 22

Relevant standards SM/TTX200/TTX300/SIL-EN TTH200, TTR200, TTH300, TTF300, TTF350 7 3 Relevant standards Standard Designation IEC 61508, Part

Page 23

Terms and definitions 8 TTH200, TTR200, TTH300, TTF300, TTF350 SM/TTX200/TTX300/SIL-EN 5 Terms and definitions Terms Definitions Dangerous f

Page 24

Safety function SM/TTX200/TTX300/SIL-EN TTH200, TTR200, TTH300, TTF300, TTF350 9 6 Safety function TTH200-.H, TTR200-.H, TTH300-.H, TTF300-.H, a

Commentaires sur ces manuels

Pas de commentaire