955 R Unsigned16 **Third last alarm
956 R Unsigned16 **Fourth last alarm
957 R Unsigned16 **Fifth last alarm
958 R Unsigned16 Sixth last alarm (not supported)
959 R Unsigned16 Seventh last alarm (not supported)
960 R Unsigned16 Eighth last alarm (not supported)
961 R Octet String4 Hardware configuration (manufacturer
specific ID of the drive)
963 R Unsigned16 Detected baud rate:
0 = 9.6 kbit/s
1 = 19.2 kbit/s
2 = 93.75 kbit/s
3 = 187.5 kbit/s
4 = 500 kbit/s
6 = 1.5 Mbit/s
7 = 3 Mbit/s
8 = 6 Mbit/s
9 = 12 Mbit/s
11 = 45.45 kbit/s
255 = Invalid baud rate
964 R Array [7] Unsigned16 Subindex Contents
0 Manufacturer
1 Device type
2Version
3 Firmware date (year)
4 Firmware date (day/month)
5 Number of Axes
6 Identification (0959h)
965 R Octet String2 Profile number of this device.
E.g. 0302h = Profile 3, Version 2
967 R Unsigned16 Control word (CW)
968 R Unsigned16 Status word (SW)